TRC® 14650013-6

Southwire® Surge Guard® 14650013-6 GFCI Outlet Adapter, 120 VAC, 15 A, NEMA 5-15R Receptacle

Price: loading
Product Information:

Additional Specifications

TRC® 14650013-6

Southwire® Surge Guard® GFCI Outlet Adapter, 120 VAC, 15 A, NEMA 5-15R, 1 Outlet, -35 to 66 deg C

Amperage Rating      :      15 A
Temperature Rating      :      -35 to 66 deg C
Receptacle      :      NEMA 5-15R
Number of Outlets      :      1
Plug Type      :      NEMA 5-15P
Voltage Rating      :      120 VAC
  • pdf Specification Sheet https://www.turtle.com//ASSETS/DOCUMENTS/ITEMS/EN/https://cdn-assets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_b3c8f6efad884d387c401ed9796f5e84e36a0b898fe2b067008df847143c78b5.pdf
  • pdf Warranty Information https://www.turtle.com//ASSETS/DOCUMENTS/ITEMS/EN/https://cdn-assets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_ffc2efbf9eb8583266633fb5b0d3857c8de0c725a2cda6036d4f903b0a5d2993.pdf
  • video Video Link https://www.youtube.com/watch?v=3etVhr84oCY
  • To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage
  • Available in yellow with button boots or white
  • Provides compliance with national electric code (NEC 2008) article 590.6 for temporary installations
  • 3-wire, 4 Ohm typical grounded neutral
  • Less than 25 ms trip response time for ground fault and grounded neutral trip
  • 4 to 6 ma trip level, mechanical indicator
  • 50/60 Hz frequency, 3 kV ringwave test and 4kv/2kA surge immunity test voltage surge withstand
  • Operates within normal limits with 0.5 volts injected on power line 150kHz to 230MHz radio frequency noise susceptibility
  • Yellow in color
  • 3000 operations minimum endurance
  • Six times rated overload current
  • 5% maximum trip level variation effect of 10 A turn DC shock on ground fault trip
  • 1500 Vrms to 1 min insulation voltage
  • Mechanical power on indicator
  • 2.65 in H x 1.75 in W x 1.975 in D
  • 314 J MOV