Eco-10® ECO-T554-120-2

Eco-10® ECO-T554-120-2

Eco-10® ECO Dimming Ballast, Fluorescent Lamp, 54 W, 120 VAC, Programmed Rapid, 1 Ballast Factor

Price: loading
Product Information:

Additional Specifications

Eco-10® ECO-T554-120-2

Eco-10® lighting management electronic dimming ballasts are designed to maximize the benefits of a lighting management system. Eco-10® offers 100% to 10% dimming and is ideal for use in any space where saving energy is the primary goal of the design.

Eco-10® Dimming Ballast, Series: ECO, Fluorescent Lamp, 54 W Lamp, 108 W, 120 VAC, 1.1 A, 60 Hz, Programmed Rapid Start, 10 deg C Minimum Starting, Total Harmonic Distortion: <20%, Power Factor: >0.95, Dimmable: Yes, 2 Lamps, Thermal Protection: Class P, Ballast Factor: 1, 75 deg C, 18 in L x 1.18 in W x 1 in H

Amperage Rating      :      1.1 A
Wattage      :      108 W
Thermal Protection      :      Class P
Series      :      ECO
Frequency Rating      :      60 Hz
Power Factor      :      >0.95
Start Type      :      Programmed Rapid
Voltage Rating      :      120 VAC
Warranty      :      5 Years
Number of Lamps      :      2
Ballast Factor      :      1
Lamp Type      :      Fluorescent
Lamp Wattage      :      54 W
Minimum Starting Temperature      :      10 deg C
Dimensions      :      18 in L x 1.18 in W x 1 in H
Dimmable      :      Yes
Total Harmonic Distortion      :      <20%
Temperature Range      :      75 deg C
  • Continuous, flicker free dimming from 100% to 10%
  • Standard 3-wire line voltage phase control technology for consistent fixture-to-fixture dimming performance
  • Programmed rapid start design preheats lamp cathodes before applying full arc voltage
  • Lamps turn on to any dimmed level without flashing to full brightness
  • Low harmonic distortion throughout the entire dimming range maintains power quality
  • Frequency of operation ensures that ballast does not interfere with infrared devices operating between 38 and 42 kHz
  • Inrush current limiting circuitry eliminates circuit breaker tripping, switch arcing and relay failure
  • End-of-lamp-life protection circuitry (for T5 and T5-HO linear models) ensures safe operation throughout entire lamp life cycle
  • For linear lamps, ballasts maintain consistent light output for different lamp lengths, ensuring fixture uniformity
  • Ultra-quiet operation
  • Protected from miswires of any input power to control lead
  • 100% compatible with all Lutron® 3-wire fluorescent controls
  • 100% performance tested at factory